CELESTRA
Observatory systems

Control & Automation

Operate the shutter and dome rotation from a PC, and coordinate the dome opening with telescope pointing.

Explore Dome Control
Permanent observatory dome with the telescope visible through its opening
Fixed observatory · rotating dome on a permanent base

How the PC and cards communicate

Commands from the PC

The observatory PC sends shutter and azimuth commands over the local Wi-Fi network. The shutter card drives the opening mechanism and the rotation card drives the dome around its base.

Status back to the PC

The controllers report shutter position signals and rotation feedback to the control software. Confirm the supported driver and network protocol for the supplied hardware.

How the dome follows the telescope

  1. The mount reports its pointing to the observatory software.
  2. The software calculates the target dome azimuth using the installation geometry and telescope offset.
  3. The rotation card moves the dome toward that target using position feedback. The shutter card handles opening and closing separately.
CELESTRA controller concept, angle view
Controller concept · angle view

Setup and verification

Set the dome’s home reference, calibrate the rotation count and verify the upper and lower shutter signals. Check alignment across several telescope positions and test stop behavior and Wi-Fi loss before unattended operation.