Fixed observatory · rotating dome on a permanent base
Two cards, separate functions
Controller concept · overhead view
Shutter control card
Drives the opening and closing mechanism and reads shutter position or limit feedback.
Upper shutter sensor
Reports the upper shutter’s position or configured travel limit.
Lower shutter sensor
Reports the lower shutter’s position or configured travel limit separately.
Controller concept · angle view
Rotation control card
Drives the dome in azimuth to align the opening with the telescope.
Home sensor
Provides a repeatable reference position for azimuth.
Pulse counting
Uses feedback from a compatible encoder or pulse sensor. Calibration maps counts from home to dome azimuth.
Where the cards fit
Controller locations on a fixed dome. Exact mounting points depend on the installation.
Wi-Fi commands and feedback
Commands from the PC
The observatory PC sends shutter and azimuth commands over the local Wi-Fi network. The shutter card drives the opening mechanism and the rotation card drives the dome around its base.
Status back to the PC
The controllers report shutter position signals and rotation feedback to the control software. Confirm the supported driver and network protocol for the supplied hardware.
Installation requirements
Confirm motor voltage and current, sensor wiring, rotation direction and counts per revolution for the supplied configuration. Verify travel limits, shutter sequencing and homing during commissioning.